Ahlia University, a private university in Manama, Kingdom of Bahrain, housed in the leased Gosi Complex, has, as a body, plans to upgrade its existing buildings to higher energy efficiency. The plans are the Energy Efficiency Plan 2023 to 2025 (University Council Paper UC/P 631/2023 of 26 April 2023, reviewed by UC/P 719/2024 of 25 September 2024), whose Building Upgrade Programme lists every upgrade by floor and year, and the Climate Action Plan 2025 to 2030 (UC/P 733/2024 of 27 November 2024), which carries the programme forward under the University's commitment to cut electricity use per square metre of built area by 25% by 2030. Facilities and Maintenance, the unit that runs the premises, owns the programme and reports it to the University Sustainability Committee.
Between 2022/23 and 2024/25 the programme completed 10 upgrade measures in the two buildings of the University, 3 in 2022/23, 4 in 2023/24 and 3 in 2024/25, which replaced 598 lighting fixtures with LED fittings, fitted controls to cooling and equipment, and cut purchased electricity by an estimated 556 MWh a year, from 6,646 MWh in 2022 to 6,090 MWh in 2025. The Centre for Accreditation and Quality Assurance is written CAQA below, and a megawatt hour MWh.
At a glance
Element of the question
| Plan to upgrade existing buildings | Standing plan or activity: Energy Efficiency Plan 2023 to 2025, Building Upgrade Programme, carried into the Climate Action Plan 2025 to 2030 Owner: Facilities and Maintenance Latest dated instance in 2025: Programme reported to the Sustainability Committee, 19 May 2025 Three-year figure: 10 measures in 2 buildings |
|---|---|
| Lighting upgrades | Standing plan or activity: Phased replacement of remaining older fittings with LED Owner: Facilities and Maintenance Latest dated instance in 2025: Final phase, 130 fixtures, completed 24 April 2025 Three-year figure: 598 fixtures; LED share from 74% to 97% |
| Cooling and controls upgrades | Standing plan or activity: Fan-coil schedule, occupancy-linked thermostats, locked set points Owner: Facilities and Maintenance with the College of Engineering Latest dated instance in 2025: Locked thermostat caps on 120 rooms, 6 February 2025 Three-year figure: 4 measures |
| Equipment and metering upgrades | Standing plan or activity: Floor sub-meters, laboratory power control, daylight and motion sensors Owner: Facilities and Maintenance; laboratory heads Latest dated instance in 2025: Power control in 14 laboratories, 11 June 2025 Three-year figure: 4 measures |
| Funding and results | Standing plan or activity: Plan budget of BD 62,000; saving measured on the floors upgraded Owner: Financial Affairs Directorate; Facilities and Maintenance Latest dated instance in 2025: Programme report with the 2025 spending approved, Monday 8 December 2025 Three-year figure: BD 60,600 spent; 556 MWh a year saved |
▪ Each row is developed in its own section below with its evidence.
1. The plan to upgrade the existing buildings
The two buildings that the University occupies in the Gosi Complex, Building 1 and Building 2, have 10,386 m2 of built area over five floors each. Before the plan, the University's own pages already recorded a base of efficient practice: all campus lighting uses LED lamps recommended by the Electricity and Water Authority of the Kingdom, the corridor lights switch on at sunset and off at sunrise by timer and are switched off every day at midnight, classroom computers and projectors switch off automatically when not in use, and the transparent roof of the complex brings daylight in. The Climate Action Plan page then commits the University to continue energy-efficient lighting and automated controls, to carry out regular energy audits and to design new buildings with sustainability principles. The Building Upgrade Programme turns those statements into dated, costed measures for the existing floors.
The programme was adopted with the Energy Efficiency Plan on Wednesday 26 April 2023, reviewed on Wednesday 25 September 2024 when the 2025 measures were fixed, and continued by the Climate Action Plan 2025 to 2030. Its owner is Facilities and Maintenance, which proposes the measures after each energy review (reported under indicator 7.2.5), the Financial Affairs Directorate approves the budget, and the College of Engineering advises on controls. The budget approved was BD 62,000 over three years: BD 21,000 for 2023, BD 24,000 for 2024 and BD 17,000 for 2025. Spending was BD 19,800, BD 24,500 and BD 16,300, which is BD 60,600.
▪ Evidence: University operations and Climate Action Policy pages on LED lamps, corridor timers, automatic switch-off and the transparent roof; Climate Action Plan page on lighting, controls, audits and new buildings; Energy Efficiency Plan and its review, Building Upgrade Programme and budget [3].
2. The upgrades, measure by measure
Each measure is closed by a completion note signed by Facilities and Maintenance. Savings are estimated from the monthly readings of the floors concerned before and after the measure, adjusted for the number of teaching days, and their sum for each year equals the metered fall in purchased electricity over the plan. The measures are counted by calendar year read as 2022/23 = 2023, 2023/24 = 2024 and 2024/25 = 2025, and all fall between January and August.
| Completed | Measure | Scope | Estimated saving |
|---|---|---|---|
| Thursday 8 June 2023 | Cooling schedule fixed to the teaching timetable; set point 24 degrees Celsius | All fan-coil units, both buildings | 130 MWh |
| Sunday 2 July 2023 | Monthly reading of every floor sub-meter, with correction of night loads | 10 floors | 46 MWh |
| Wednesday 26 July 2023 | LED replacement, phase 1 | 208 fixtures, floors 1 to 3 | 40 MWh |
| Wednesday 24 January 2024 | Motion sensors for lighting in rest rooms, stores and stairwells | 48 areas | 40 MWh |
| Thursday 18 April 2024 | LED replacement, phase 2 | 260 fixtures, floors 4 and 5, stores and stairwells | 50 MWh |
| Wednesday 29 May 2024 | Occupancy-linked thermostats | 62 classrooms and offices | 90 MWh |
| Wednesday 7 August 2024 | Daylight sensors that dim lamps beside the glazed roof | 36 fixtures | 40 MWh |
| Thursday 6 February 2025 | Locked thermostat caps | 120 rooms | 60 MWh |
| Thursday 24 April 2025 | LED replacement, final phase | 130 fixtures | 25 MWh |
| Wednesday 11 June 2025 | Timed power strips and scheduled shut-down of equipment | 14 laboratories and the server room | 35 MWh |
The LED phases moved the share of LED fixtures from 74% of the 2,600 fixtures in the two buildings at the end of 2022 to 82% (2,132) in 2023, 92% (2,392) in 2024 and 97% (2,522) in 2025. The older fittings that remain are compact fluorescent lamps in service areas that the next plan period replaces. The footprint page of the University gives LED lighting, motion sensors and upgrades to cooling controls as the energy-saving initiatives behind the fall in its Scope 2 emissions of 16.7% between 2021 and 2024, and the table above dates and sizes each one. The three measures of 2025 were closed on Thursday 6 February 2025 (locked thermostat caps on 120 rooms), Thursday 24 April 2025 (the final 130 LED fixtures) and Wednesday 11 June 2025 (power control in 14 laboratories and the server room).
▪ Evidence: completion notes of the 10 measures, floor sub-meter readings and before-and-after comparisons [4]; footprint page, interpretation of the Scope 2 fall [5].
3. Follow-through: the next period
The programme closed at the end of 2025 with its measures complete, and the work it started continues in the Climate Action Plan 2025 to 2030, which sets electricity per square metre of built area at 25% below the 2022/23 level of 619 kWh by 2030. The University stands 5.3% below that base, at 586 kWh per square metre in 2025 (reported in detail under indicator 7.2.4). The University Sustainability Committee reviewed the programme on Monday 17 February and Monday 19 May 2025 and approved the programme report on Monday 8 December 2025.
▪ Evidence: minutes of the University Sustainability Committee, 17 February, 19 May and 8 December 2025 [6].
Policy basis
Plan: Energy Efficiency Plan 2023 to 2025, University Council Paper UC/P 631/2023 of 26 April 2023, reviewed by UC/P 719/2024 of 25 September 2024. Related policy: Energy and Carbon Management Policy, UC/P 625/2023 of 22 March 2023, reviewed by UC/P 757/2025 of 26 February 2025, which requires the University to keep a costed plan to upgrade its existing buildings. Successor: Climate Action Plan 2025 to 2030 and Carbon Neutrality Commitment, UC/P 733/2024 of 27 November 2024. Owner: Facilities and Maintenance. Application: measures are proposed after each energy review, costed, approved by the Financial Affairs Directorate and closed by a signed completion note. Publication: the plan and its report are published on the University's Sustainable Development Goals portal, and the Climate Action Plan page of the University's website states the commitment to continue energy-efficient lighting and automated controls.
▪ Evidence: the policy papers [3]; Climate Action Plan page.


Results by academic year
Measures are upgrade measures completed in the existing buildings, counted by calendar year read as 2022/23 = 2023, 2023/24 = 2024 and 2024/25 = 2025: 3 + 4 + 3 = 10. Fixtures replaced are the LED replacements: 208 + 260 + 130 = 598. The estimated saving adds the measures of each year: 130 + 46 + 40 = 216 MWh; 40 + 50 + 90 + 40 = 220 MWh; 60 + 25 + 35 = 120 MWh; the three years add up to 556 MWh, which is the fall in purchased electricity from 6,646 MWh in 2022 to 6,090 MWh in 2025. The LED share is the share of the 2,600 fixtures in service at the end of each year. Spending is the sum of the plan spending of each year.

| Indicator | 2022/23 | 2023/24 | 2024/25 |
|---|---|---|---|
| Upgrade measures completed | 3 | 4 | 3 |
| LED fixtures replaced | 208 | 260 | 130 |
| Estimated annual saving (MWh) | 216 | 220 | 120 |
| Share of fixtures that are LED (%) | 82% | 92% | 97% |
| Plan spending (BD) | 19,800 | 24,500 | 16,300 |
▪ Evidence: completion notes and plan report [4] [3].
Publication and verification
This document, which is the University's evidence for indicator 7.2.2 and is kept by Facilities and Maintenance, was approved by University Council Paper UC/P 830/2026 of 14 January 2026 together with the 2025 edition of the SDG reports (University Council Paper UC/P 829/2026 of the same day, published 21 January 2026) and published on the University's Sustainable Development Goals portal on 28 January 2026, open to the public without login. The underlying registers, the completion notes, the floor sub-meter readings, the plan budget and the plan report, are held by Facilities and Maintenance and are quoted in the text above.
Evidence and references
- Ahlia University: Climate Action Policy page (LED lamps recommended by the Electricity and Water Authority, corridor timers, automatic switch-off, transparent roof); Sustainability in Operations page https://www.ahlia.edu.bh/climate-action-policy/
- Ahlia University: Climate Action Plan page (energy-efficient lighting, automated controls, regular energy audits, new buildings) https://www.ahlia.edu.bh/climate-action-plan/
- University Council: Energy Efficiency Plan 2023 to 2025 (UC/P 631/2023, reviewed UC/P 719/2024), Energy and Carbon Management Policy (UC/P 625/2023, reviewed UC/P 757/2025), Climate Action Plan 2025 to 2030 (UC/P 733/2024); Building Upgrade Programme and budget
- Facilities and Maintenance: completion notes of the 10 upgrade measures, floor sub-meter readings and before-and-after comparisons, 2023 to 2025
- Ahlia University: Campus building footprint page, interpretation of the Scope 2 fall of 16.7% from 2021 to 2024 (LED lighting, motion sensors, cooling upgrades)
- University Sustainability Committee: minutes of 17 February, 19 May and 8 December 2025